Obsnap Instruments Sdn Bhd
29A, Jalan SS 15/4C, 47500 Subang Jaya, Selangor, Malaysia.
+603-5621 5786
+603-5621 5829
+60122185651 (Enquiry)
+60162233687 (Vacancy)
High-Temperature Tube Furnaces for Horizontal and Vertical Operation up to 1800ˇăC Gas Atmosphere or Vacuum
Previous | 8 / 13 | Next |
View old post here
The high-temperature tube furnaces are available in either horizontal (type RHTH) or vertical (type RHTV) designs. High-quality insulation materials made of vacuum-formed fiber plates enable energy-saving operation and a fast heating time due to low heat storage and heat conductivity. By using different gas supply systems, operations can be performed under non-flammable or flammable protective or reactive gases or under vacuum.
- Tmax 1600 °C, 1700 °C, or 1800 °C
- MoSi2 heating elements, mounted vertically for easy replacement
- Insulation with vacuum-formed ceramic fiber plates
- Only fiber materials are used which are not classified as carcinogenic according to TRGS 905, class 1 or 2
- Rectangular outer housing with slots for convection cooling
- Tube furnaces RHTV with frame for vertical operation
- Dual shell housing made of sheets of textured stainless steel
- Ceramic working tube made of material C 799 incl. fiber plugs for operation under air
- Type B thermocouple
- Power unit with low-voltage transformer and thyristor
- Over-temperature limiter with adjustable cutout temperature for thermal protection class 2 in accordance with EN 60519-2 as temperature limiter to protect the furnace and load and with selectable maximum temperature gradient as tube protection
- Switchgear and control unit separate from furnace in separate floor standing cabinet
- Defined application within the constraints of the operating instructions
- NTLog Basic for Nabertherm controller: recording of process data with USB-flash drive
Additional equipment
- Charge control with temperature measurement in the working tube and in the furnace chamber outside the tube
- Display of inner tube temperature with additional thermocouple
- Gas tight flanges for protective gas and vacuum operation
- Manual or automatic gas supply system
- Three-zone control for optimization of temperature uniformity (only tube furnaces RHTH)
- Check valve at gas outlet avoids intrusion of false air
- Process control and documentation via VCD software package or Nabertherm Control Center (NCC) for monitoring, documentation and control
Model Horizontal design |
Tmax °C | Outer dimensions in mm | Max. outer tube Ø/mm | Heated length mm | Length constant temperature ±5K | Tube length in mm | Connected load kW | Electrical connection | Weight in kg | ||
---|---|---|---|---|---|---|---|---|---|---|---|
W | D | H | |||||||||
RHTH 50/150/.. | 1600 or | 470 | 480 | 640 | 50 | 150 | 50 | 380 | 5.4 | 3-phase | 70 |
RHTH 80/300/.. | 1700 or | 620 | 550 | 640 | 80 | 300 | 100 | 530 | 9.0 | 3-phase | 90 |
RHTH 120/600/.. | 1800 | 920 | 550 | 640 | 120 | 600 | 200 | 830 | 14.4 | 3-phase | 110 |
Model Vertical design |
Tmax °C | Outer dimensions in mm | Max. outer tube Ø/mm | Heated length mm | Length constant temperature ±5K | Tube length in mm | Connected load kW | Electrical connection | Weight in kg | ||
---|---|---|---|---|---|---|---|---|---|---|---|
W | D | H | |||||||||
RHTV 50/150/.. | 1600 or | 500 | 650 | 510 | 50 | 150 | 30 | 380 | 5.4 | 3-phase | 70 |
RHTV 80/300/.. | 1700 or | 580 | 650 | 660 | 80 | 300 | 80 | 530 | 10.3 | 3-phase | 90 |