Previous 17 / 24 Next

Fluoride Portable Photometers HI96729 Photometers  Water / Liquid Analysis

Quantity
Add Quotation


The HI96729 Fluoride Low Range Portable Photometer combines accuracy and ease of use in an ergonomic, portable design. A user can accurately determine the concentration of fluoride within a 0.00 to 2.00 mg/L (ppm) range using the HI93729-01 ready made reagents. The HI96729 offers many advanced features including the exclusive CAL Check™ function used for performance verification and calibration of the meter.
  • CAL Check™ Validation and Calibration
  • Built-in Timer
  • Automatic Shut Off

Details

The HI96729 portable photometer is for the low range measurement of fluoride. Hanna's portable photometers feature an advanced optical system; the combination of a special tungsten lamp, a narrow band interference filter, and silicon photodetector ensure accurate photometric readings every time. The Hanna exclusive CAL Check feature utilizes ready-made, NIST traceable standards to verify both meter validation and calibration. The exclusive cuvette locking system ensures that the cuvette is inserted into the measurement cell in the same position every time to maintain a consistent path length.

Features at-a-glance

CAL Check™ - Allows for performance verification and calibration of the meter using NIST traceable standards.

GLP - Review of the last calibration date.

Auto-shut off - Automatic shut off after 10 minutes of non-use when the meter is in measurement mode. Prevents wastage of batteries in the event the meter is accidentally left on.

Battery status indicator - Indicates the amount of battery life left.

Built-in timer - Display of time remaining before a measurement is taken. Ensures that all readings are taken at the appropriate reaction intervals for the test being performed.

Error messages - Messages on display alerting to problems including no cap, high zero, and standard too low.

Cooling lamp indicator - To maintain the desirable wavelength to be used for absorbance, it is necessary to ensure components are not overheated from the heat generated by the tungsten lamp. Each photometer is designed to allow a minimal amount of time for components to cool. The cooling lamp indicator is displayed prior to a reading being taken.

Units of measure - Appropriate unit of measure is displayed along with reading.

Specifications

Range 0.00 to 2.00 mg/L (ppm)
Resolution 0.01 mg/L (ppm)
Accuracy @ 25°C (77°F) ±0.03 mg/L ±3% of reading
Light Source tungsten lamp
Light Detector silicon photocell with narrow band interference filter @ 575 nm
Method adaptation of the EPA method 340.1 and SPADNS method
Auto-off after ten minutes of non-use in measurement mode; after one hour of non-use in calibration mode; with last reading reminder
Environment 0 to 50°C (32 to 122°F); RH max 95% non-condensing
Battery Type 9V battery
Dimensions 193 x 104 x 69 mm (7.6 x 4.1 x 2.7”)
Weight 360g (12.7oz.)
Ordering Information HI96729 is supplied with sample cuvettes (2) with caps, 9V battery, instrument quality certificate and instruction manual. CAL Check™ standards and testing reagents sold separately.
Warranty  2 years

 

Please leave your enquiry here, we will reply as soon as possible.
Name*  
Company Name  
Product Interested  
Quantity  
Email*  
Contact No.*  
Ship to Name  
Shipping Address  
Attachment  
*only support gif, jpeg, jpg, png, pdf
Messages*  


You have 0 items in you cart. Would you like to checkout now?
0 items
Switch to Mobile Version
available in
Subscribe Newsletter