Obsnap Instruments Sdn Bhd
29A, Jalan SS 15/4C, 47500 Subang Jaya, Selangor, Malaysia.
+603-5621 5786
+603-5621 5829
+60122185651 (Enquiry)
+60162233687 (Vacancy)
Elektrophysik - High voltage Pinhole Detector - PoroTest 7
Previous | 1 / 2 | Next |
Transportable high voltage Holiday Detector to locate pores, cracks and other faults in insulating materials (e.g. varnish, synthetic material, rubber, bitumen) on conductive substrates (e.g. steel, aluminium, earth-moist concrete constructions) as per DIN 55670.
The Holiday Detector, PoroTest 7, is specially designed to test functionally critical insulating layers, e.g. inner and outer linings of tanks and pipelines in the field of petrochemicals, anti-corrosion coatings in shipbuilding, protective coatings of sewage tanks etc.
The electronically controlled high voltage source unfailingly prevents the test voltage from exceeding and dropping below limit, a feature not provided in low-cost devices. Exceeding the limit can cause damage to the coating to be tested; dropping below the limit prevents detection of pores.
A wide range of special electrodes are available; we can also fabricate customised inner, outer and plate electrodes as per application requirement of the client.
Overview
Technical details
The Holiday Detector, PoroTest 7, is specially designed to test functionally critical insulating layers, e.g. inner and outer linings of tanks and pipelines in the field of petrochemicals, anti-corrosion coatings in shipbuilding, protective coatings of sewage tanks etc.
The electronically controlled high voltage source unfailingly prevents the test voltage from exceeding and dropping below limit, a feature not provided in low-cost devices. Exceeding the limit can cause damage to the coating to be tested; dropping below the limit prevents detection of pores.
A wide range of special electrodes are available; we can also fabricate customised inner, outer and plate electrodes as per application requirement of the client.
Overview
Technical details
Property | Value | ||||||||
---|---|---|---|---|---|---|---|---|---|
Operating range |
|
||||||||
Coating thickness |
|
||||||||
Voltage |
|
||||||||
Test voltage indication |
|
||||||||
Accuracy of voltage setting |
|
||||||||
Dimensions and weight |
|
||||||||
Alarm signal |
|
||||||||
Signal output |
|
||||||||
Storage battery |
|
||||||||
Storage battery life at maximum voltage |
|
||||||||
Storage battery charging time |
|
||||||||
Mains Voltage |
|
||||||||
Operating temperature |
|
||||||||
Humidity |
|
||||||||
Standards |
|